NT Part 13.4 Building sealing
NCC Blurbs
This Part applies to—
- a Class 1 building; and
- a Class 10a building with a conditioned space.
Applications
This Part does not apply to:
- A building where the only means of air-conditioning is by using an evaporative cooler.
- A permanent building ventilation opening that is necessary for the safe operation of a gas appliance.
- A Class 10a building used for the accommodation of vehicles.
NCC SPTC Current
Application of Part 13.4
NCC ID
_409cfe24-f064-4d58-908d-711b05ec0377
NCC Blurbs
The chimney or flue of an open solid-fuel burning appliance must be provided with a damper or flap that can be closed to seal the chimney or flue.
NCC SPTC Current
Chimneys and flues
NCC ID
_1ff5c2fd-1c2f-421d-aab0-a877f426a827
NCC Blurbs
(2) A roof light required by (1) must be constructed with—
- an imperforate ceiling diffuser or the like installed at the ceiling or internal lining level; or
- a weatherproof seal if it is a roof window; or
- a shutter system readily operated either manually, mechanically or electronically by the occupant.
NCC SPTC Current
Roof lights
NCC ID
_ba6918bb-ac38-4203-84cf-9894454288bf
NCC Blurbs
(1) A seal to restrict air infiltration must be fitted to each edge of an external door, openable window and other such opening when serving a conditioned space.
(2) The following need not comply with (1):
- An external louvre door, louvre window or other such opening.
- A window complying with the maximum air infiltration rates specified in AS 2047.
(3) A seal required by (1) may be a foam or rubber compressible strip, fibrous seal or the like.
NCC Title
External windows and doors
NCC SPTC Current
External windows and doors
NCC ID
_27f1f15b-78bc-4ea0-add6-763fa56544d7
NCC Blurbs
An exhaust fan must be fitted with a sealing device such as a self-closing damper, filter or the like when serving a conditioned space.
Explanatory information
An exhaust fan is considered to be adequately sealed if it is fitted with a filter such as the type commonly used in kitchen range hoods.
NCC SPTC Current
Exhaust fans
NCC ID
_fdd10516-cf3a-433f-bd31-03aaf673b38d
NCC Blurbs
(1) Ceilings, walls, floors and any opening such as a window frame, door frame, roof light frame or the like must be constructed to minimise air leakage in accordance with (2) when forming part of the external fabric a conditioned space.
(2) Construction required by (1) must be—
- enclosed by internal lining systems that are close fitting at ceiling, wall and floor junctions; or
- sealed at junctions and penetrations with—
- by close-fitting skirting, architraves, cornices; or
- expanding foam, rubber compressive strip, or caulking, or the like.
NCC Title
Construction of ceilings, walls and floors
NCC SPTC Current
Construction of ceilings, walls and floors
NCC ID
_519803b3-ad51-489e-ba6f-34a37eb36d20
NCC Blurbs
An evaporative cooler must be fitted with a self-closing damper or the like when serving a heated space.
Explanatory information
The self-closing damper should create an effective seal against air infiltration.
NCC SPTC Current
Evaporative coolers
NCC ID
_6b62c929-65d2-476f-86b4-9237a9157fd0