NCC 2022 Volume One - Building Code of Australia Class 2 to 9 buildings
Filter
I6
NSW Part I6 Drive-in theatresNSW Part I6 Drive-in theatres
Introduction to this Part
NSW Part I6 contains Deemed-to-Satisfy Provisions for drive-in theatres.
Deemed-to-Satisfy Provisions
NCC Blurbs
This Part applies to drive-in theatres.
NCC Title
Application of Part
NCC State
NSW
NCC SPTC Current
Application of Part
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Speaker standards must—
- be placed at a minimum of 5.5 m centres in a line along each parking ramp; and
- be capable of being illuminated throughout any performance so as to be easily distinguishable at all times.
NCC Title
Speaker standards
NCC State
NSW
NCC SPTC Current
Speaker standards
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Lines of speaker standards along parking ramps must be placed at a distance of not less than 12.2 m apart.
NCC Title
Lines of speaker standards
NCC State
NSW
NCC SPTC Current
Lines of speaker standards
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
The following electrical services must be installed underground—
- the supply authority’s conductors within the site and the consumer’s mains, unless otherwise approved; and
- electrical wiring external to any building on the site; and
- all wiring to the speaker standards.
NCC Title
Electrical services
NCC State
NSW
NCC SPTC Current
Electrical services
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Each public vehicular entrance to or exit from the drive-in theatre must be capable of being fully illuminated by flood lights that are so placed and so focussed as not to interfere with the vision of the driver of any motor vehicle.
NCC Title
Vehicular entrances
NCC State
NSW
NCC SPTC Current
Vehicular entrances
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
NCC Title
Lighting
NCC State
NSW
NCC SPTC Current
Lighting
Building Classes
1a,1b,10a,10b,10c