TAS Part I11 FoundriesTAS Part I11 Foundries
Introduction to this Part
This Part contains additional requirements for foundries.
Deemed-to-Satisfy Provisions
NCC Blurbs
NCC Title
Application of Part
NCC State
TAS
NCC SPTC Current
Application of Part
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
- where a ceiling is provided, measured from the floor to the ceiling; or
- where a ceiling is not provided, measured from the floor to the lowest part of the roof.
NCC Title
General
NCC State
TAS
NCC SPTC Current
General
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
- of heavy timber or non-slip steel plate; and
- securely fixed in position; and
- level.
- a wall, not less than 1 m high, measured from the floor of the platform, constructed to surround the platform; and
- the side between the top of the wall and the roof suitably waterproofed an ventilated.
NCC Title
Cupola charging platform
NCC State
TAS
NCC SPTC Current
Cupola charging platform
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Deep moulds or pits, for permanent use—
- must be lined with bricks, concrete, or other suitable material in such a manner as to provide adequate reinforcement and to keep the pit or mould in a dry condition; and
- must be securely fenced by means of a wall of adequate construction, railings or chains and stanchions raised, in each case, to a height not less than 1 m above the surface of the surrounding floor.
NCC Title
Deep moulds and pits
NCC State
TAS
NCC SPTC Current
Deep moulds and pits
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Where pot furnaces are below ground level, the pit must be covered by a substantial grating at the point at which metal is removed from the furnace, and must at all other times be securely fenced as in TAS I11D4(b)
NCC Title
Pot furnaces
NCC State
TAS
NCC SPTC Current
Pot furnaces
Building Classes
1a,1b,10a,10b,10c